Preview only show first 10 pages with watermark. For full document please download

Facts_and_cont.ppt

ppt

   EMBED


Share

Transcript

A presentation on….. FACTS  FACTS DEVICES??  BENEFITS OF FACTS MAINTENA NCE OF FACTS  MAINTENANCE  OPERATION OF FACTS IDENTIF ICATION TION OF O F FACTS  IDENTIFICA  FUTURE ENHANCEMENTS Flexible  Alternating Current Transmission System FACTS as they are generally known, are new devices that improve transmission systems. 1. Static VAR Compensators (SVC’s) 2. Thyristor controlled series compensators (TCSCs) 3. STATCOM 4. Unified Power Flow Controller (UPFC) Benefits of utilizing FACTS devices : UPFC CIRCUIT DIAGRAM  Better utilization of existing transmission system assets  Increased transmission system reliability and availability  Increased dynamic and transient grid  stability and reduction of loop flows  Increased quality of supply for sensitive industries  Environmental benefits TECHNICAL BENEFITS OF MAIN FACT DEVICE Voltage Limits Low Voltage at Supply Reactive Shunt capacitor, SVC, heavy loads Power  Series STATCOM Capacitor  TCSC, High voltage at Remove light load Reactive Power  supply TCSC, Switch EHV SVC, Line and\or  STATCOM shunt capacitor  Absorb Reactive Power  Switch Shunt SVC,STATCOM capacitor, Shunt Reactor  High voltage Absorb following Reactive outage Power  Add shunt SVC,STATCOM reactor  Protect Equipment Add arrestor  SVC Low Voltage Supply reactive Switch Shunt SVC,STATCOM following  power  capacitor, Outage reactor, series capacitor  Prevent Series Reactor, TCPAR,TCSC Thermal Limits Line or  Reduce Transformer  Overload Overload Add line or  TCSC, UPFC, TCPAR  transformer  Add series SVC, TCSC reactor  Tripping of  Limit Circuit Add series UPFC, TCSC Parallel loading reactor, circuit (line) capacitor  Loop flows Parallel line Adjust series Add series UPFC, TCSC load sharing reactance capacitor/reac tor  Adjust phase Add PAR  angle Post-fault sharing Rearrange network use TCPAR,UPFC PAR, Series TCSC,UPFC,SVC,TCP or  Capacitor/ AR  Reactor  “Thermal Limit” actions Flow Direction Adjust Phase PAR  TCPAR,UPFC Short Circuit Levels Excessive breaker  Limit Short-circuit Add series Reactor, new fault currents currents circuit breaker  Change  breaker  Sub Sync. resonance Potential Turbine Circuit Add new circuit Breaker  Rearrange network  Split Bus Mitigate Oscillations Series Compensation Investment costs of FACTS devices a) The devices’ equipment costs, and (b) The necessary infrastructure costs 160 160 140 120 140 120 STATCOM 100 80 100 80 SVC 60 60 40 20 40 20 100 200 300 400 500 UPFC T CSC FSC. 100 200 300 400 500 FINANCIAL BENEFITS: 1. Additional sales 2. Additional wheeling charges 3. Avoiding or delaying of investments Maintenance of FACTS devices  is minimal and similar to that required for shunt capacitors, reactors and transformers  The amount of maintenance ranges from 150 to 250 man-hours per  year  Operation of FACTS devices  operated automatically  can be done locally and remotely Steps for the Identification of FACTS  Projects:  Performance Verification Projects to conduct a detailed network study to investigate the critical conditions of a grid   For a stable grid, the optimized utilization of the transmission lines could be investigated  an economical study can be performed to compare costs of FACTS devices or conventional solutions with the achievable benefits. Performance Verification The design of all FACTS devices should be tested in a transient network analyzer (TNA)   The results of the TNA tests should be consistent with the results of the network study Bibliography: .   Electrical power systems by C.L.Wadhawa, new age publishers www.abb.com www.siemens.com