Preview only show first 10 pages with watermark. For full document please download

Kane 940 Operating Manual

Instruction Manual for the Kane Flue Gas analyser

   EMBED


Share

Transcript

    KANE940 Hand-held Combustion Analyser Kane International Limited  Kane House, Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Tel: +44 (0) 1707 375550 Fax: +44 (0) 1707 393277 E-mail: [email protected] www.kane.co.uk Stock No: 18115 February 2006 © Kane International Limited   - 2 - CONTENTS Page No:  1. ANALYSER LAYOUT AND FEATURES............................................................4-7 1.1 Instrument features and keypad...........................................................................4 1.2 Instrument layout (Rear).....................................................................................5 1.3 Standard Probe Configuration.............................................................................6 1.4 Analyser connections..........................................................................................7 2. SAFETY WARNING...................................................................................................8 3. FIRST TIME USE........................................................................................................8 4. NORMAL START UP SEQUENCE......................................................................9-15 4.1 Every Time You Use The Analyser....................................................................9 4.2 Automatic Calibration.........................................................................................9 4.3 Main Display Parameters..................................................................................11 4.3.1 4 Page Mode.........................................................................................11 4.3.2 Line Scroll Mode..................................................................................12 4.3.3 8 Page Mode.........................................................................................12 4.4 Sampling the Flue Gas......................................................................................13 4.5 Taking a Pressure Reading................................................................................13 4.6 Regular Checks During Sampling.....................................................................14 4.7 Normal Shutdown Sequence.............................................................................14 4.8 Electromagnetic Compatibility.........................................................................15 5. MOVING THROUGH THE MENUS..................................................................16-22 5.1 Basic Operation.................................................................................................16 5.2 Menu Options and Settings...............................................................................17 5.2.1 Main Menu............................................................................................17 5.2.2 Select Menu..........................................................................................17 5.2.3 Units Menu............................................................................................19 5.2.4 Display Menu........................................................................................20 5.2.5 Set-Up Menu.........................................................................................20 6. PRINTING INFORMATION.....................................................................................23 6.1 Printing a ‘Live’ Test..........................................................................................23 6.2 Standard Printout................................................................................................23 7. STORING AND RETRIEVING DATA..............................................................24-25 7.1 Storing a ‘Live’ Test.........................................................................................24 7.2 Viewing and Printing a ‘Stored’ Test................................................................24 7.3 Deleting Data.....................................................................................................25   - 3 - 8. MAINTENANCE.......................................................................................................26 8.1 Emptying and Cleaning the in-line water trap..................................................26 8.2 Changing the particle filter................................................................................26 9. PROBLEM SOLVING...............................................................................................27 10. ANNUAL RE-CALIBRATION.................................................................................27 11. PRODUCT SPECIFICATION.............................................................................28-29 APPENDICES: A. MAIN DISPLAY PARAMETERS............................................................................30 B. COMBUSTION EFFICIENCY CALCULATION...............................................32-33 C. CALCULATION OF FUEL DATA...........................................................................34 D. ELECTROMAGNETIC COMPATABILITY STATEMENT...................................35   - 4 - 1. ANALYSER LAYOUT AND FEATURES 1.1 Instrument Features and Keypad  ON/OFF UP Scrolls up through options ie Fuel MENU Allows access to all menu functions  DOWN Scrolls down through options PUMP Turns pump on and off STORE Enters data storage menu ENTER Accepts a command ie enters a menu option PRINT Prints current data Flue Temperature Connector (underside)RS232 (8 pin din)Charger socketStorePrintPumpEnter Menu On/Off Up Down Keypad Inlet Port (side) Pressure Inlet Infra-red emitter